The use of an ambient temperature of 32 to 131 F (0 to 55 C)
Sense of type J or K type thermocouple sensor sensor
Temperature sensor range 32 to 860 F (0 to 450 C)
Temperature accuracy of plus or minus 0.5 degrees Celsius
Insurance protection AC/220V 15A dual fast fuse
Output type bidirectional thyristor 15A 220V AC 3600W
Temperature control card power supply 86240V AC 50/60Hz
Functions and features
A, over-voltage and over-current protection, when the error of access 380 volt power supply, electronic circuit protection dog instant start from the state.
To take the wrong line will not burn out temperature control card, automatically enter the working state after the correct connection;
Two, thermocouple disconnection, short circuit, reversed when the alarm sounds and fault code display, and automatic cutting controller
Three, the temperature error of plus or minus 0.5 degrees, FUZYY+PID control algorithm, PID parameter has an online automatic tuning
Two ways with manual setting;
Four, open circuit alarm function, the temperature control device with automatic recognition of heater burn, disconnection and alarm function.
At the same time code display, automatic cut-off control output;
Five, the output power that can automatically detect the output power of heating (A);
Six, with a soft start hot runner heating mode, the hot runner dehumidification preheating effect, to protect the Guan Yan fever
Long service life, soft start heating power and heating time can be set free;
Seven, can be set to K type and J type two thermocouple sensor signal, accurate temperature nonlinear processing and integration of the
The cold end compensation control mode for zero trigger mode, PWM output pulse width adjustment;
Eight, the temperature set degrees Celsius and Fahrenheit two ways and display;
Nine, the upper limit temperature alarm function, temperature alarm function, the upper / lower limit temperature can be set;
Ten, in addition to the automatic control system, it is also equipped with a manual control mode, for special cases (temperature line breaker)
Lower heating mode.